Is the AS-Interface cable (yellow and black) silicone-free ?

  • The cable is silicone screting free.

How do you exchange data via Profibus DP between a Moeller PLC with a CM4-504/LE4-504/PS416-NET-441 and a Siemens S7/C7?

  • Use Siemens system function SFC13/SFC14/SFC15.

How can you display I/O status information and other modules in the DP Configurator, and how do you force the outputs?

  • Click on the question to obtain information.

What is the pin assignment of the KPG3-PS3 cable ?

  • Click on the question to obtain information.

How can you connect a PROFIBUS-DP master and a PROFIBUS-DP slave to the PS4-341-MM1 together?

  • Click on the question to obtain information.

How much data can a PS416-NET-440 Profibus DP master card send to each station and how much can it receive ?

  • The PS416-NET-440 can receive 244 bytes and send 244 bytes.

What is the current hardware version of the PS3AC and PS3DC ?

  • The current hardware version (12/2000) of the PS3AC and PS3DC is : Version 1.7

How is the Merten EIB Gateway integrated for Suconet K1 using S40?

  • Use the SIS-TYP-80D6 remote expansion module in the Topology Configurator.

What earth cable is recommended for Suconet K?

  • LAPP KABEL Unitronic-Bus Yv L2/FIP

On which PC operating systems does the PROFIBUS-FMS Configurator run ?

  • From version 3.3 or higher, MS-Windows 95, MS-Windows 98 and MS-Windows NT. Before this version, only MS-Windows 3.xx.

Is there a German version of the Profibus DP Configurator ?

  • Click on the question to obtain information.

Can the COBOX be connected via the screw terminals?

  • Yes, for more informations click on the question to obtain information.

How can consistent data be received with a Profibus DP master?

  • By adjustment of the consistent data length

Is it possible to use the DE4-NET-K network module with DF4-120 frequency inverters ?

  • The DE4-NET-K network module cannot be used with DF4-120 frequency inverters. The module is used to connect the DF4-340 and DF4-341 frequency inverters directly to the Suconet K fieldbus.

How can you prepare your own Suconet K/K1 cable ?

  • Use LT309.096 cable and connector S1-PS3.

How do you implement communication with PS4/PS416 programmable controllers via TCP/IP on Ethernet

  • Communication with PS4/PS416 programmable controllers via TCP/IP on Ethernet can be implemented using the ″Cobox″.

What cable can be used for PROFIBUS-DP ?

  • Click the question to obtain the technical data of the cable.

Is the AS-Interface flat cable halogen-free ?

  • Yes, the sheething consists of a halogen-free rubber mixture (EM3) in accordance with VDE 0207 Part 31.

Is it possible to run a Suconet K2 line with the PS416 ?

  • The PS416-NET-210 Suconet K1/K2 card and the S40-AM-K2-D/GB application module are required for running Suconet K2 with the PS416.

Do the PS4 compact PLCs have a MODBUS/JBUS interface ?

  • A MODBUS/JBUS interface can be implemented using the S40-AM-K4-D/GB application module and an interface converter.

How can large volumes of data be transferred via Suconet K or PROFIBUS-DP ?

  • The Suconet K/PROFIBUS-DP data multiplexer application module enables the transfer of large data volumes.

How can you expand an AS-Interface network ?

  • With repeaters and / or extenders.

Is it possible to mix the operation of AS-Interface slaves to
specification 2.0 and 2.1 on the same line ?

  • Yes

Do AS-Interface applications require the use of a special AS-Interface power supply unit ?

  • Yes

Are the AS-i modules from the EM2 series still available?

  • No, click the question to obtain more infos.

Is there a data multiplexer for Suconet-K / PROFIBUS-DP ?

  • Yes, the application module S40-AM-K1-GB contents a data multiplexer for Suconet-K / PROFIBUS-DP.

Which PS4 type can be equipped with the PROFIBUS-DP master module ?

  • Only the PS4-341-MM1.

How is the current version of the Profibus-DP Configurator for S40 available ?

  • Over download, please click on the question.

Are the LE4-504-BT1 and PS416-NET441 PROFIBUS-DP slave modules certified by the Profibus User Organisation (PNO) and the Underwriter Laboratories (UL) ?

  • Yes

What is the maximum number of slave stations that can be run with the
LE4-504-BS1 (PROFIBUS-DP master) ?

  • 124 Slaves

How many LE4-505-BS1 and CM4-505-GS1 AS-Interface masters can be connected to a PS4-... ?

  • Click on the question to obtain information.

How many stations can be connected to an AS-Interface master LE4-505-BS1 and CM4-505-GS1 ?

  • 31 stations.

Is it possible to implement an MV4 interface via Device Net ?

  • Yes, with MV4 configurator MV4-CFG-1 since version 3.12.4 and a communication card ZB4-606-IF1.

What design measures are required to integrate an LE4-504-BT1 (PROFIBUS-DP Slave) in a STEP 7 hardware configuration?

  • The design measures for integrating an LE4-504-BT1 (PROFIBUS-DP Slave) in a STEP 7 hardware configuration are shown in a video that can be downloaded.

How can an MV4 touch panel be connected to a Siemens S7 PLC?

  • An MV4 touch panel can be connected to a Siemens S7 PLC using PROFIBUS-DP.

How can PS4/PS416 systems be networked with PROFIBUS-FMS?

  • Different modules/cards are available for networking PS4/PS416 systems with PROFIBUS-FMS. Click the question to obtain further information.

How can the PS416 networked with PROFIBUS-PA?

  • The PS416 can be networked with PROFIBUS-PA using a segment coupler.

How are PS416 systems networked using the PS416-NET-400 Suconet K network card?

  • Click the question above to obtain a description of the networking of PS416 systems.

How many stations can be connected to an AS-Interface master CM4-505-GV1 and CM4-505-GV2 ?

  • 62 stations.

Can the CoBox also be run on the Suconet (RS485) interface?

  • On the PS4-341-MM1 the CoBox can also be run directly on the Suconet interface if the SucomA function block is called in Transparent mode.

Is there a software to support the PROFIBUS-DP link of the Easy control relay to the EASY204-DP module with a MOELLER control system PS4 / PS416 ?

  • The S40-AM-K6-D/GB application module is provided for this purpose. Click the question to obtain the application module via the Internet.

Can the PS4/PS416 communicate via Ethernet ?

  • For the communication with Ethernet is the network-module ″COBOX″ available.

What is the application module required for data exchange between the PS40 controller via Ethernet?

  • The application module is: S40-AM-K5-GB, to download please click on the question.

Which hardware components are required for connecting a PS40 controller to an Ethernet network ?

  • The following devices are required:
    CoBox and ZB4-501-UM3(-UM4)

What is the name of the manual for AS-i Profibus-Gateways (CM4-505-GV1/GV2) ?

  • The article-number is AWB2700-1409-GB.
    The manual is available on the Moeller homepage => support => Quick Search to: CM4-505.

What is the application module for Ethernet data coupling with the
PS4-150/-200/-341 and PS416 ?

  • Yes, the application module S40-AM-K5-GB. With clicks the question to download.

What is the name of the configuration software for the AS-i safety monitor?

  • AS4-505-CF1

What are the type designations for the AS-i safety monitors:
a) 1-channel; b) 2-channel?

  • a) AS4-505-MO1 b) AS4-505-MO2

What is the correct course of action when diagnostics status message:
″ Unexpected Type ″

  • Please check the version number, the version 01 or 03 and higher is o.k.

What is the name of the download cable for the safety configuration of the PC in the AS-i safety monitor?

  • You need the cable ZB2-505-KB1, to download the safety configuration from the PC to the safety monitor.

What is the name of the data exchange cable (SM - SM) of the safety configuration for one safety monitor to another safety monitor ?

  • ZB2-505-KB2

Is there any particular PLC required for AS-i safety control ?

  • No, the safety control system is implemented using a additional safety monitor (AS4-505-MO1/-MO2).

After a new configuration, the AS-Interface monitor cannot be switched to protection mode and signals the entry of an incorrect password. Why ?

  • A new password must be defined. The preset password of the safety monitor is SIMON. After an application has been created, however, a new password that is different to SIMON must be defined in order to enable protection mode.

Can a safety slave (AS-Interface) be assigned to several safety monitors ?

  • When a monitor is configured, it is assigned with the safety slaves required for the application. It does not matter whether these slaves are also used by another monitor.

What reaction time can be reached with AS-Interface Safety at Work ?

  • The max. reaction time of AS-Interface Safety at Work is 40 ms.

Can safety information be transferred via the AS-Interface ?

  • The use of electronic devices for safety applications is permissible if the same level of safety is to be achieved as for conventional devices. For AS-Interface safety at work, this must be certified with the relevant test certificates.

Can a faulty safety AS-i slave exchanged without a new configuration of the safety monitor ?

  • Yes, please click on the question to obtain further information.

How can you program PS4- / PS416 controllers via Ethernet ?

  • Please click on the question to obtain further information

What is required to program PS4-.../PS416 controllers via Ethernet ?

  • Please click on the question to obtain further information.

Where can I get information on Moeller LON products ?

  • Click the question to obtain further information.

Is there a software to support the PROFIBUS-DP link of the Easy control relay with the EASY204-DP module to the Siemens S7-300 ?

  • The S7-AM-K6-D/GB application module is provided for this purpose.

Can DF5 and DV5 series frequency inverters be connected to PROFIBUS-DP?

  • Yes

How do I implement the DeviceNet interfacing of an Easy 600 to a SLC 500 from Allen Bradley ?

  • Please click on the question to obtain further information !