Switching, Control, Communication – Simply Easy

 

The Clever Control Relay easy500, easy700 and easy800

The new easy500 and easy700 control relays offer all the technical features of the tried and tested easy400 and easy600 devices and also include a lot of new functions.

These control relays are a universal system which feature common software and operation: for intelligent solutions in the fields of mechanical engineering and instruments. The easy800 control relay combines practically all the performance features of a PLC with the well-known simple handling features of easy. easy800 allows you – thanks to the integrated networking of up to 8 devices – to implement applications with more than 300 I/O points.

Technical Data Overview






The following applies for all easy units:
Connection cables
0.2 – 2.5 mm², flexible/ 0.2 – 4.0 mm², solid
Degree of protection IP 20
Interference suppression EN 55 011/55 022 class B
Operating
temperature
-25°C to +55°C
Transport and storage temperature -40°C to + 70°C
Certification, standard EN 50 178, IEC/EN 60947, UL, CSA
Fitting On a top-hat rail to DIN 50 022, 35 mm or
screw fixing with ZB4-101-GF1 fixing bracket.






500 basic units
Application: Stand-alone operation
EASY...
512-
AB-RC
AB-RX
512-
AC-R
512-
AC-RC
AC-RCX
512-
DA-RC
DA-RCX
512-
DC-R
512-
DC-RC
DC-RCX
512-
DC-TC
DC-TCX
Supply voltage
24 V AC
100 – 240 V AC
12 V DC

24 V DC
Heat dissipation
5 V A
5 V A
2 W

2 W
Inputs,
digital
8
8
8
8
8
8
8
Inputs,
analog 0 – 10 V (optional)
2
2
2
2
2
Outputs,
digital (R=relay, T=transistor)
4 R
4 R
4 R
4 R
4 R
4 R
4 T
Outputs,
analog (0 – 10 V)
LCD display/
keypad EASY
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
LCD display/
keypad EASY.-.X
–/–
–/–
–/–
–/–
–/–
7-day/
year time switch
Yes/Yes
–/–
Yes/Yes
Yes/Yes
–/–
Yes/Yes
Yes/Yes
Continuous current outputs
8 A
8 A
8 A
8 A
8 A
8 A
0.5 A
Short-circuit proof with
power factor 1

Line protection B 16, 600 A
Short-circuit proof with power factor 0.7... 0.7

Line protection B 16, 900 A
Dimensions
(W x H x D) mm
71.5 x 90 x 58 mm






700 basic units
Application: Expandable, (EASY2..., EASY6...)
EASY ...
719-
AB-RC
AB-RCX
719-
AC-RC
AC-RCX
719-
DA-RC
DA-RCX
719-
DC-RC
DC-RCX
721-
DC-TC
DC-TCX
Supply voltage
24 V AC
100 - 240 V AC
12 V DC
24 V DC
Heat dissipation
7 V A
10 V A
3.5 W
3.5 W
Inputs,
digital
12
12
12
12
12
Inputs,
analog 0 – 10 V
(optional)
4
4
4
4
Outputs,
digital (R=relay,T=transistor)
6 R
6 R
6 R
6 R
8 T
Outputs,
analog, (0 – 10 V)
LCD display/
keypad EASY
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
LCD display/
keypad EASY.-.X
–/–
–/–
–/–
–/–
–/–
7-day/
year time switch
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Continuous current outputs
8 A
8 A
8 A
8 A
0.5 A
Short-circuit proof
with power factor 1
Line protection B 16, 600 A
Short-circuit proof with power factor 0.7... 0.7
Line protection B 16, 900 A
Connection cables
0.2 – 4.0 mm² (AWG 22-12), solid
0.2 – 2.5 mm² (AWG 22-12), flexible
Degree of protection
IP 20
RFI suppression
EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4
Ambient operating temperature
-25° C ... + 55° C
Transport and storage temperature
- 40° C ... + 70° C
Certification,
standards
EN 50178, IEC/EN 60947, UL, CSA
Mounting
On top-hat rail to DIN 50022, 35 mm
or screw mounting with ZB4-101-GF1 fixing brackets
Dimensions
(W x H x D) mm
107.5 x 90 x 58 mm






800 series basic units, expandable, including networking features
EASY ...
819-
AC-
RC
819-
AC-
RCX
819-
DC-
RC
819-
DC-
RCX
821-
DC-
TC
821-
DC-
TCX
820-
DC-
RC
820-
DC-
RCX
822-
DC-
TC
822-
DC-
TCX
Supply
voltage
115/240 V AC
24 V DC
Power dissipation
10 VA
3.4 W
Inputs,
digital
12
12
12
12
12
12
12
12
12
12
Inputs,
analog,
option
(0–10 V)
4
4
4
4
4
4
4
4
Outputs,
digital (R=relay,
T=transistor)
6 R
6 R
6 R
6 R
8 T
8 T
6 R
6 R
8 T
8 T
Outputs,
analog,
(0–10 V)
1
1
1
1
LC display,
keypad
Yes
Yes
Yes
Yes
Yes
Week/
Year clock
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Yes/Yes
Output
continuous current
8 A
8 A
8 A
8 A
0.5 A
0.5 A
8 A
8 A
0.5 A
0.5 A
Short-circuit proof
at cos phi = 1
Line protection B 16, 600 A
Line protection
B 16, 600 A
Short-circuit proof
at cos phi =
0.5...0.7
Line protection B 16, 900 A
Line protection
B 16, 600 A
Dimensions
(W x H x D) mm
107.5 x 90 x 72 mm






Expansions
Digital inputs/outputs
Expansions
Communication
EASY...
618-
AC-
RE
618-
DC-
RE
620-
DC-
TE
202-
RE
200-
EASY
204-
DP
205-ASI
221-
CO
222-
DN
Supply
voltage
115/240 V AC
24 V DC
24 V DC
24 V DC
24 V DC
Power dissipation
10 VA
4 W
1 W
1 W
2 W
1 W
2 W
2 W
Inputs,
digital
12
12
12
Inputs,
analog,
option (0-10 V)
Outputs,
digital (R=relay
T=transistor)
6 R
6 R
8 T
2 R
Outputs,
analog,
(0-10 V)
LC display,
keypad
Week/
Year clock
–/–
–/–
–/–
–/–
–/–
–/–
–/–
–/–
–/–
Output
continuous current
8 A
8 A
0.5 A
8 A
Short-circuit proof
at cos phi = 1
Line protection
B 16, 600 A
B 16,
600 A
Short-circuit proof
at cos phi=
0.5...0.7
Line protection
B 16, 900 A
B 16,
900 A
Dimensions
(W x H x D) mm
107.5 x 90 x 58 mm
35.5 x 90 x 58 mm






Switching mode power supplies
EASY ...
200-POW
400-POW
Input voltage range
85 to 264 V AC
85 to 264 V AC
Output voltage
24 V DC +/- 3%
24 V DC +/- 3%
Output current, nominal value
0.25 A
1.25 A
Overcurrent limitation
from 0.3 A
from 1.4 A
General
Auxiliary output voltage 12 V DC, 20 m A for analog supply
Potential isolation,
primary/secondary
Yes, SELV
(to EN 60 0950, VDE 805)
Yes, SELV
(to EN 60 0950, VDE 805)
Short-circuit proof (secondary)
Yes
Yes
Overload protection (secondary)
Yes
Yes
Dimensions
(W x H x D) mm
35.5 x 90 x 58 mm
71.5 x 90 x 58 mm

 

Online Catalogue

Here you find your application!
 
Exchange information with other users in the Easy-Forum!
  Note: You will exit the moeller.net with this link. Moeller GmbH does not assume any responsibility for the content and design of the linked pages.